If the boundary wire is damaged or incorrectly connected, the LED indicator on the charging station flashes green. Damage can be caused, for example, by stretching the wire too tightly or digging with a shovel. In regions where there is frost on the ground, sharp stones moving in the ground can also cause the cable to break. Mowing grass too low can also damage the cable insulation. Defective insulation can then lead to interruptions weeks or months later.
What can you do?
Firstly, carry out a visual inspection for obvious damage. This is often enough to find and repair the interruption, especially with cables laid above ground.
If you cannot see the damage, you can localise it using a perimeter wire tester, for example. Defective areas can then be repaired with a cable connector or a repair kit for robotic lawnmowers.
To do this, connect the two open cable ends with the cable connector or use the repair kit for more extensive damage. You can obtain further information and the required material from our service centre. The spare part number for the repair kit is 91105165, for the cable connector 91105164.